CGFCC - ENAMEL ALKYD, LUSTERLESS LOW VOC BROWN 3011

  • MSDS: CGFCC
  • Manufacturer: N P
  • Product Name: ENAMEL ALKYD, LUSTERLESS LOW VOC BROWN 3011
  • National Stock Number: 8010-00-598-5462
Product Identification

Contractor
PRATT AND LAMBERT INC
6027 CLEVELAND, OH 44101-1027 US

Telephone: 216-566-2902

Cage: 61196

Ingredients

METHYL ISOAMYL KETONE (SOLVENT)

CAS: 110-12-3

RTECS: MP3850000

Fraction By Weight: 5.0%

OSHA PEL 50 PPM; 240 MG/M3

ACGIH TLV: 50 PPM; 240 MG/M3

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:UNKNOWN IARC:YES
Health Hazards Acute and Chronic:ACUTE; INGEST: GASTROINTESTINAL IRRIT,
NAUSEA, VOMITING. ASPIRATION INTO LUNG MAY CAUSE CHEM PNEUMONITIS
(CAN BE FATAL). INHAL: NOSE OR THROAT IRRIT. ACUTE CENTRAL NERVOUS
SYSTEM DEPRESSION (HEADACHES , DIZZINESS, NAUSEA, CONFUSION). EYE:
SEVERE IRRIT. SK
Explanation of Carcinogenicity:IARC CONSIDERS CRYSTALLINE SILICA TO
HAVE LIMITED EVIDENCE OF CARCINOGENICITY IN HUMANS/SUFFICIENT IN
ANIMALS.
Effects of Overexposure:CHRONIC; SILICOSIS (DISABLING LUNG DISEASE).
LIVER, KIDNEY AND BLOOD INJURY. ENHANCES NEUROTOXICITY (SYNERGISTIC
EFFECT RESULTED IN PERIPHERAL NEUROPATHY). PROLONGED & REPEATED
OVEREXPOSURE: PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE.
CONCENTRATING & INHALI
Medical Cond Aggravated by Exposure:PRE-EXISTING RESPIRATORY CONDITIONS
MAY BE AGGRAVATED BY EXPOSURE TO CRYSTALLINE SILICA.

First Aid

First Aid:INGEST: DONT INDUCE VOMITING. CALL POISON CTR/EMERG ROOM/DR
IMMED. INHAL:REMOVE TO FRESH AIR IMMED. IF BREATHING STOPPED, GIVE
ARTIF RESPRTN. KEEP WARM & QUIET. GET MED AID IMMED. EYE: FLUSH
W/WATER 1 5 MIN, LIFTING EYELIDS. GET MED AID. SKIN: REMOVE CONT

Accidental Release

Spill Release Procedures:WEAR RSPRTR,EYE,HAND,BODY PROTECTN. KEEP
SPECTATORS AWAY. ELIMINATE IGNIT SOURCES. DIKE & CONTAIN W/INERT
MAT'L (SAND/EARTH/ETC). TRANSFER LIQ/USED ABSORBENT TO COVERED
METAL CONTAINER. USE NON-SPARKI NG TOOLS. PREVENT SEWER,GROUNDWATER
CONTAMINATION.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 115 F. STORE LARGE
QUANTITIES IN COMPLIANCE WITH OSHA 29 CFR 1910.106. DO NOT TAKE
INTERNALLY. DO NOT BREATHE SANDING DUST.
Other Precautions:CLOSE CONTAINER AFTER EACH USE. DO NOT WASH & REUSE
EMPTY CONTAINER FOR ANY PURPOSE. GROUND & BOND CONTAINERS TO
RECEIVING CONTAINER. DO NOT WELD, BRAZE, OR CUT ON EMPTY CONTAINER.
NEVER USE PRESSURE TO EMPTY. DRUM IS NOT A PRESSURE VESSEL.

Exposure Controls

Respiratory Protection:IF VENTD,MAY NOT REQ RSPRTR.IN RESTRICTD VENT,
NIOSH CHEM CARTRIDGE RSPRTR MAY BE REQ'D.SPRAYNG,MECHAN PREFILTER
MAY ALSO BE REQ'D.CONFIND AREAS,USE AIR SUPPLD RSPRTR.SEE OSHA
29CFR1910.134"RESP PROTE CT"&"RESP PROTECT-MANUAL & GUIDELINE"AIH
Ventilation:LOCAL EXHAUST VENT TO KEEP BELOW TLV. REMOVE DECOMPOSITION
PRODUCT. SEE "INDUST VENT-MANUAL RECOMMENDED PRACTICES" ACGIH
Protective Gloves:SOLVENT IMPERMEABLE GLOVE-REPEAT/PROLONG
Eye Protection:WEAR SAFETY SPECTACLES
Other Protective Equipment:EYEWASH FACILITY, SAFETY SHOWER.
Supplemental Safety and Health

Stability

Hazardous Decomposition Products:BURNING, INCLUDING WHEN HEATED BY
WELDING OR CUTTING, WILL PRODUCE SMOKE, CARBON MONOXIDE & CARBON
DIOXIDE.

Disposal

Product ID:ENAMEL ALKYD, LUSTERLESS LOW VOC BROWN 3011
MSDS Date:01/01/1987
FSC:8010
NIIN:00-598-5462
MSDS Number: CGFCC

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH FEDERAL, STATE &
LOCAL LAWS/REGULATIONS. INCINERATE IN EPA PERMITTED FACILITY. DONT
INCINERATE CLOSED CNTNRS. OBSERVE PRECAUTIONS FOR DISPOSAL OF
FLAMMABLE MATERIALS. RCRA C LASSIFICATION: D001.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.